The following 35 products are eligible
3118云顶集团(中国区)官方网站
NPEXA-C01H
1 input and 1 output contrast
Temperature input isolated barrier, it converts the thermocouple/thermal resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.
3118云顶集团(中国区)官方网站
NPEXA-C011H
1 input and 2 outputs contrast
Temperature input isolated barrier, it converts the thermocouple/thermal resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.nt power supply.
3118云顶集团(中国区)官方网站
NPEXA-C0D11
2 inputs and 2 outputs contrast
Temperature input isolated barrier, it converts the thermocouple/thermal resistance signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.ation terminals. It needs an independent power supply.
3118云顶集团(中国区)官方网站
NPEXA-C11H
1 input and 1 output contrast
Temperature input isolated barrier, it converts the thermocouple signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.
3118云顶集团(中国区)官方网站
NPEXA-C111H
1 input and 2 outputs contrast
Temperature input isolated barrier, it converts the thermocouple signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.It has external cold junction compensation terminals. It needs an independent power supply. The input, output,
3118云顶集团(中国区)官方网站
NPEXA-C1D11
2 inputs and 2 outputs contrast
Temperature input isolated barrier, it converts the thermocouple signals from a hazardous area into 4~20mA signals to a safe area by isolation. It has external cold junction compensation terminals. It needs an independent power supply. The input, output, and power supply are galvanically isolated from each other. The self-test function is also available on this device. Calibrate the apparatus or modify parameters by using a handheld programmer.